Flex-Tex Installation Instructions

last revision: 3/1/03

To install Flex-Tex Joint Sealant, follow these easy installation instructions. Proper assembly will result in a form-in-place, high-density gasket that conforms to the sealing surfaces and fills in surface voids and irregularities.
  1. Select a Joint Sealant width that is 1/3-1/2 of the flange sealing surface width. A guideline for round, 150# & 300# ANSI flanges is as follows:
    Flange SizeJoint Sealant Size
    Up to 1/2"1/8"
    3/4" to 1-1/2"3/16"
    2" to 4"1/4"
    5" to 8"3/8"
    10" to 16"1/2"
    18" to 24"5/8"
    24" to 36"3/4"
    36" and above1"
  2. Clean seal surface of dirt, grease and all other forms of debris.
  3. Measure and cut off a length of Joint Sealant that is several inches longer than the mean length of the seal surface. Joint ends must overlap.
  4. Remove the peel-off backing.
  5. As diagrammed below, beginning to the left of a bolt hole, apply FLEX-TEX clock-wise to the flange surface inside the bolt hole circle, overlapping the ends in an "X" fashion.
    Installation Diagram
  6. Bolt up mating surfaces. Torque in a "star-type" pattern, and in steps, preferably 60%, 90%, and finally 100%. It may be necessary to make a repeat pass at 100% in the event some relaxation occurs.